10 HP Sanitary Rotary Lobe Pump, SS304/SS316L
$2,586.51 原价为:$2,586.51。$1,820.50当前价格为:$1,820.50。
We have available a sanitary design rotary lobe pump with a listed 10 HP (7.5 kW) Siemens motor which operates on any of the voltages 220, 380 or 440. This pump is designed to move high viscosity process fluids. Depending on the fluid and your application you can specify the construction of the pump to be SS304 or SS316L. Contact us to further assist you in selecting the best pump for your application.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
Overview
Our sanitary stainless steel rotary lobe pump is used in processing to transfer higher viscosity products. The drive shown is a 10 HP, 3-phase Siemens motor which can also be ordered at 220 V, 380 V or 440 V. Pump bodies can be fabricated from type 304 or 316 stainless steel depending on the user’s preference.
The rotary lobe pump transfers product to another part of the system; it does not guarantee a specified flow or pressure. To determine the minimum flow and pressure required to transfer the product, further testing should be conducted by the user. The construction of this pump does not indicate compliance to any regulatory or hygienic standard.
Function
Two intermeshed rotors with a lobed shape, resembling gears, create a pumping action to draw fluid into the pump body and transfer it to the outlet. This action is known as positive displacement. The capability of a rotary lobe pump to transport product is greater at lower speeds. To avoid damage to the pump seals the rotors should not be run dry.
Key Features
10 HP (7.5 kW) Siemens motor – As indicated above, the drive has a rating of 10 HP, however other drive speeds and ratings may be used with this pump.
Check the frequency of the motors, and ensure the connections and voltage are correct before purchasing.
Select SS304 or SS316L material depending on what the pump comes in contact with. Take into account the temperature and the type of product being transferred to ensure the pump has adequate compatibility.
Centrifugal pumps can’t always be used to move some types of liquid. The lobes of the pump can be used to transport viscous liquids.
The orientation of the pump can effect how it’s integrated into the process. Take into account the orientation and type of seals used to integrate the pump into the process.
Because of the variety of materials and seals available this pump can be used to transfer viscous products in the food and beverage industry and other sectors. The compatibility of the product being transferred should be assessed with respect to the pump to determine its suitability.
A rotary lobe pump is supplied with a 10 HP (7.5 kW), Siemens motor and can operate with a voltage of 220, 380 or 440. SS304 or SS316L are available as the wetted materials. The pump is designed to transfer high viscosity liquids.
Flow rate and pressure are variables that are not provided in the data sheet. Other variables that may be different for each specific application include the type of seal used and the operating temperature range.
Don’t assume the motor or clean-in-place capabilities of this pump unless they have been explicitly specified.
Why Use This Pump?
Although several considerations need to be addressed prior to specifying this pump for a particular application, users interested in construction of a viscous fluid line may find it useful to check motor compatibility and determine the supply voltage to suit their needs. Based upon the design and material of construction of this pump, it could be applicable to a wide range of process fluids. Other design considerations include the operating temperature of the process fluid and the type of cleaning fluid. The final judgment as to the performance of the pump and its ability to meet the process requirements should be made by the system designer.
To evaluate this pump for use in a given application the user should provide the required flow rate, discharge pressure and viscosity of the process fluid to be pumped. Further information such as the type and concentration of any suspended solids, cleaning agents and the total operating time would also be useful in evaluating the suitability of the pump. Other information such as the pipe diameter, length and the type of connection, would also be helpful to the pump supplier to assess its applicability to the process.
What is the operating limit of this pump?
This pump is designed to handle high viscosity fluids in a process application. Users should contact the supplier to determine applicability for a given process.
What types of liquids can this pump handle?
No pump should be assessed based on viscosity of the fluid to be handled. Consideration should be given to temperature of the process fluid, the type and concentration of suspended solids and the type of cleaning fluid.
Information on flow rate, pressure and speed is not provided.
Which supply voltage should I select?
The available options are 220V, 380V and 440V. Determine the plant supply voltage, frequency of the power line and the type of wiring with the electrical department of the user agency as well as the supplier to select the appropriate model.
Should SS304 or SS316L be specified?
Select the material based on the fluid being pumped and the environment to which the pump is exposed.
Is a sanitary design construction of a pump certified to any standard?
No certification should be inferred from a description of sanitary construction. Request documentation to confirm compliance with the standards of interest prior to placing an order.
To provide a quotation what information should be provided?
Indicate the fluid to be pumped, the required flow rate and pressure, operating temperature range, voltage and frequency of the power supply, the type of connections, environment in which the pump will be installed, and any post installation cleaning requirements and/or certifications.
Request a Pump Configuration
Provide the destination supply voltage, frequency and type of power as well as any additional process information relevant to the application to assist in defining the requirements of the pump and other components to be supplied. We will provide a quotation based on this information.
Overview
Our sanitary stainless steel rotary lobe pump is used in processing to transfer higher viscosity products. The drive shown is a 10 HP, 3-phase Siemens motor which can also be ordered at 220 V, 380 V or 440 V. Pump bodies can be fabricated from type 304 or 316 stainless steel depending on the user’s preference.
The rotary lobe pump transfers product to another part of the system; it does not guarantee a specified flow or pressure. To determine the minimum flow and pressure required to transfer the product, further testing should be conducted by the user. The construction of this pump does not indicate compliance to any regulatory or hygienic standard.
Function
Two intermeshed rotors with a lobed shape, resembling gears, create a pumping action to draw fluid into the pump body and transfer it to the outlet. This action is known as positive displacement. The capability of a rotary lobe pump to transport product is greater at lower speeds. To avoid damage to the pump seals the rotors should not be run dry.
Key Features
10 HP (7.5 kW) Siemens motor – As indicated above, the drive has a rating of 10 HP, however other drive speeds and ratings may be used with this pump.
Check the frequency of the motors, and ensure the connections and voltage are correct before purchasing.
Select SS304 or SS316L material depending on what the pump comes in contact with. Take into account the temperature and the type of product being transferred to ensure the pump has adequate compatibility.
Centrifugal pumps can’t always be used to move some types of liquid. The lobes of the pump can be used to transport viscous liquids.
The orientation of the pump can effect how it’s integrated into the process. Take into account the orientation and type of seals used to integrate the pump into the process.
Because of the variety of materials and seals available this pump can be used to transfer viscous products in the food and beverage industry and other sectors. The compatibility of the product being transferred should be assessed with respect to the pump to determine its suitability.
A rotary lobe pump is supplied with a 10 HP (7.5 kW), Siemens motor and can operate with a voltage of 220, 380 or 440. SS304 or SS316L are available as the wetted materials. The pump is designed to transfer high viscosity liquids.
Flow rate and pressure are variables that are not provided in the data sheet. Other variables that may be different for each specific application include the type of seal used and the operating temperature range.
Don’t assume the motor or clean-in-place capabilities of this pump unless they have been explicitly specified.
Why Use This Pump?
Although several considerations need to be addressed prior to specifying this pump for a particular application, users interested in construction of a viscous fluid line may find it useful to check motor compatibility and determine the supply voltage to suit their needs. Based upon the design and material of construction of this pump, it could be applicable to a wide range of process fluids. Other design considerations include the operating temperature of the process fluid and the type of cleaning fluid. The final judgment as to the performance of the pump and its ability to meet the process requirements should be made by the system designer.
To evaluate this pump for use in a given application the user should provide the required flow rate, discharge pressure and viscosity of the process fluid to be pumped. Further information such as the type and concentration of any suspended solids, cleaning agents and the total operating time would also be useful in evaluating the suitability of the pump. Other information such as the pipe diameter, length and the type of connection, would also be helpful to the pump supplier to assess its applicability to the process.
What is the operating limit of this pump?
This pump is designed to handle high viscosity fluids in a process application. Users should contact the supplier to determine applicability for a given process.
What types of liquids can this pump handle?
No pump should be assessed based on viscosity of the fluid to be handled. Consideration should be given to temperature of the process fluid, the type and concentration of suspended solids and the type of cleaning fluid.
Information on flow rate, pressure and speed is not provided.
Which supply voltage should I select?
The available options are 220V, 380V and 440V. Determine the plant supply voltage, frequency of the power line and the type of wiring with the electrical department of the user agency as well as the supplier to select the appropriate model.
Should SS304 or SS316L be specified?
Select the material based on the fluid being pumped and the environment to which the pump is exposed.
Is a sanitary design construction of a pump certified to any standard?
No certification should be inferred from a description of sanitary construction. Request documentation to confirm compliance with the standards of interest prior to placing an order.
To provide a quotation what information should be provided?
Indicate the fluid to be pumped, the required flow rate and pressure, operating temperature range, voltage and frequency of the power supply, the type of connections, environment in which the pump will be installed, and any post installation cleaning requirements and/or certifications.
Request a Pump Configuration
Provide the destination supply voltage, frequency and type of power as well as any additional process information relevant to the application to assist in defining the requirements of the pump and other components to be supplied. We will provide a quotation based on this information.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.