5.5 kW Sanitary Lobe Pump with Explosion-Proof VFD Motor
$2,779.75 原价为:$2,779.75。$1,873.87当前价格为:$1,873.87。
We offer a 5.5 kW variable frequency explosion-proof motor rotor lobe pump made of stainless steel to transfer high viscosity fluids. To determine the best pump for your process, include additional information such as the operating pressure, properties of the fluid to be transferred, and any pasteurization or other requirements for cleansing. Also include the classification of the hazardous area.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
Make sure you have the correct area classification and motor markings prior to purchase.
Lobe pumps utilize impellers to transfer product through defined paths. Therefore, lobe pumps work well to transport viscous products that other types of centrifugal pumps may have difficulty transferring.
Some potential uses of this pump may include transferring viscous ingredients in food and beverage manufacturing, or in the manufacture of personal care products. Where the pump is constructed of sanitary materials it may also be suitable for use in other areas of a processing plant as well. For product and process verification the end user should assess the viscosity and other attributes of the product to be transported and ensure the pump is compatible with the cleaning solutions used to clean the pump.
Confirmation of rotor material, elastomers and mechanical seals should also be requested prior to purchase. In addition users should determine the voltage, frequency, and phase of the electrical supply to which the explosion proof motor will be connected. In hazardous locations, the user should also request the motor’s level of protection to confirm suitability for that location.
A sanitary lobe pump, with an explosion proof motor and variable speed control is a good choice for transferring thick or viscous fluids in a processing line. The speed of the explosion proof motor also allows it to be adjusted to regulate the flow rate of the product being transported.
Specifying the wetted materials, seals, and operating pressures as early in the design process helps minimize the risk of misalignment between the pump package and the production line.
To choose the appropriate pump configuration provide the approximate flow rate and discharge pressure of the fluid to be pumped. If the fluid is shear thinning, provide the shear sensitivity of the fluid as well as the viscosity at the operating temperature. Also indicate the composition of the fluid including any solids that may be present. Indicate how the pump will be connected to the system, in what direction it will be mounted, and the voltage available at the site. For explosive area applications identify the area classification to enable us to specify the motor and impeller appropriate for that application.
What is the application of this 5.5 kW sanitary lobe pump?
Rotary lobe pumps are used to transfer high viscosity fluids. Determine the suitability of this pump for your service by comparing the physical properties of the fluid to be pumped with the characteristics of the pump. How does a rotary lobe pump operate to transfer the fluid? The rotors turn and create a partial vacuum that draws fluid into the pump and conveys it around the casing of the pump to the outlet.
The rotors are interconnected and will always operate together.
Can the variable frequency motor be used to adjust flow rate?
Variable frequency drives can adjust the speed of the motor and thus the flow of the pump. The extent of flow adjustability is dependent upon the process limits and the configuration of the control system.
What does it mean if the motor is explosion proof?
Only an explosion proof motor, in conjunction with other components of the pump, may make the device suitable to be used in a hazardous location. To confirm this you would need to review the documentation for the device against the local and national codes pertaining to your location.
Does this pump have approval for use in food or pharmaceutical service?
Unless specified in the product description, no assumption should be made regarding the approval of this device for any particular service.
To receive a quote for this product what information should be included?
You should provide the properties of the fluid to be pumped, the flow rate and pressure required, the operating temperature range, the connections and electrical supply available, as well as the environment in which the pump will be installed.
What type of pump do you need?
Contact us to discuss the specific requirements of your process and we will suggest an appropriate pump configuration.
Make sure you have the correct area classification and motor markings prior to purchase.
Lobe pumps utilize impellers to transfer product through defined paths. Therefore, lobe pumps work well to transport viscous products that other types of centrifugal pumps may have difficulty transferring.
Some potential uses of this pump may include transferring viscous ingredients in food and beverage manufacturing, or in the manufacture of personal care products. Where the pump is constructed of sanitary materials it may also be suitable for use in other areas of a processing plant as well. For product and process verification the end user should assess the viscosity and other attributes of the product to be transported and ensure the pump is compatible with the cleaning solutions used to clean the pump.
Confirmation of rotor material, elastomers and mechanical seals should also be requested prior to purchase. In addition users should determine the voltage, frequency, and phase of the electrical supply to which the explosion proof motor will be connected. In hazardous locations, the user should also request the motor’s level of protection to confirm suitability for that location.
A sanitary lobe pump, with an explosion proof motor and variable speed control is a good choice for transferring thick or viscous fluids in a processing line. The speed of the explosion proof motor also allows it to be adjusted to regulate the flow rate of the product being transported.
Specifying the wetted materials, seals, and operating pressures as early in the design process helps minimize the risk of misalignment between the pump package and the production line.
To choose the appropriate pump configuration provide the approximate flow rate and discharge pressure of the fluid to be pumped. If the fluid is shear thinning, provide the shear sensitivity of the fluid as well as the viscosity at the operating temperature. Also indicate the composition of the fluid including any solids that may be present. Indicate how the pump will be connected to the system, in what direction it will be mounted, and the voltage available at the site. For explosive area applications identify the area classification to enable us to specify the motor and impeller appropriate for that application.
What is the application of this 5.5 kW sanitary lobe pump?
Rotary lobe pumps are used to transfer high viscosity fluids. Determine the suitability of this pump for your service by comparing the physical properties of the fluid to be pumped with the characteristics of the pump. How does a rotary lobe pump operate to transfer the fluid? The rotors turn and create a partial vacuum that draws fluid into the pump and conveys it around the casing of the pump to the outlet.
The rotors are interconnected and will always operate together.
Can the variable frequency motor be used to adjust flow rate?
Variable frequency drives can adjust the speed of the motor and thus the flow of the pump. The extent of flow adjustability is dependent upon the process limits and the configuration of the control system.
What does it mean if the motor is explosion proof?
Only an explosion proof motor, in conjunction with other components of the pump, may make the device suitable to be used in a hazardous location. To confirm this you would need to review the documentation for the device against the local and national codes pertaining to your location.
Does this pump have approval for use in food or pharmaceutical service?
Unless specified in the product description, no assumption should be made regarding the approval of this device for any particular service.
To receive a quote for this product what information should be included?
You should provide the properties of the fluid to be pumped, the flow rate and pressure required, the operating temperature range, the connections and electrical supply available, as well as the environment in which the pump will be installed.
What type of pump do you need?
Contact us to discuss the specific requirements of your process and we will suggest an appropriate pump configuration.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.