How To Adjust The Starting Oil Quantity Of The Rotary Lobe Pump

The lobe pump needs to open all the inlet and outlet valves of the pipeline before starting, and it is strictly forbidden to idle the pump. If a filtering device is installed at the work site, the filtering device should be cleaned regularly every month.

Before the lobe pump is started, it is also necessary to check whether the oil quantity in the gear box is normal, observe the transparent oil mark, the oil stock is appropriate to half of the oil mark sight window, the lubricant should be replaced regularly, in general, after 4000 hours of operation, all should be replaced.

In the first month of operation of the lobe pump, after 100 hours change the oil, after each 500 hours, change the oil once. Regularly check the wear of the bushings, which should be replaced in time after greater wear.

Zhejiang Ace Pump Technology Co., Ltd. is a large comprehensive pump company integrating design, research and development, production and sales of lobe pumps, rotary lobe pumps and rubber lobe pumps. Its products are widely used in the fields of grease, petrochemical, clearing and sweeping tanks, underground and high speed railway sewage, breeding sewage, food waste disposal and so on. Over the years, the company has been focusing on the technical research, production and manufacturing of various types of pumps, and is committed to providing customers with applicable pump handling system solutions.