Cont

Have any Questions?

+86 18626835909

May 14, 2022 View:

The lobe rotor pump does not produce media

Cam lobe pump does not discharge media

Solution

Air not exhausted from inlet and outlet lines


When you choose a Ace pump, you not only get the pump, but you also get the advantage of Ace's engineering expertise and years of application knowledge in your industry.

Follow Us:

Contact Us

  • [email protected]
  • +86 18626835909
  • No.545, Jinhai 3rd Avenue, Wenzhou Economic-Technological Development Zone, Wenzhou, Zhejiang, China

Categories

News Letter

Enter your email to subscribe to us

Ace Pumps Co., Ltd. All rights reserved

Serial number

Cause

1

Air leak inlet and outlet lines

Check and plug

2

Inlet and outlet valves not open

Open inlet and outlet valves

3

Inlet and outlet lines are clogged

Check and clean

4

Exhaust air

5

Pump cavity or radial liner wear

Replace radial liner

6

Axial liner wear

Replacement of axial liner

7

Worn or broken rotor

Replacement of rotor

8

No liquid in pump chamber, dry rotation

Add medium

9

Pump not rotating

Check and troubleshoot, and refer to 2

10

rotation in opposite direction

adjustment

11

if there is a bypass device, the device valve is open

<

Close device valve

12

Low speed

Adjust RPM

13

Pump suction diameter too large

Match with pump suction diameter