Electric Sanitary Gear Pump for Edible Oil, Low Pressure
$2,530.00 原价为:$2,530.00。$1,759.79当前价格为:$1,759.79。
We offer an automatic control electric stainless steel sanitary gear pump for transfer of edible oils at low pressure. This gear pump employs a positive displacement design to move oil in tank transfers, processing and filing. Send us the particulars of your application including the flow rate and operating pressure of the oil, power and control signal, and we will let you know the best version to use and provide a price quote.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
Check to see if a variable speed drive or pressure control valve is provided with the pump.
Low Pressure Service
Only pumps with ratings for low pressure service should be used for these applications. When selecting a pump verify that it will operate with the resistance in the system to develop the required discharge pressure.
Edible Oil Applications
Pumps in this service may be used to transfer edible oils from one location to another, or to supply oil to process equipment. When transferring oils factors such as the oil’s viscosity, length and elevation of the pipe run, and the presence of restrictions in the line must be considered to determine if the pump will provide sufficient flow for the application.
Configuration and Selection Considerations
Prior to purchase verify the type of oil to be transferred, viscosity, operating temperature, required flow and pressure, and the material of construction for the rotor and seals. Also determine the connections to be made to the inlet and outlet of the pump as well as the type and voltage of the electric motor to be used to drive the pump. For automatic control of the pump, determine the operation and control sequence to be utilized with the equipment to be integrated with the production process. Do not assume any food contact approvals or control components are included with the pump.
This configuration allows for the transfer of edible oils using an electrically controlled stainless steel pump. Other control components may also be required to integrate this pump with the user’s system. To avoid control and performance issues with the pump, user should supply additional information regarding the system with which the pump is to be integrated.
What oil is this pump designed to transfer?
Edible oils.
Verify the oil type and viscosity to confirm compatibility with the pump.
Also confirm operating temperature.
How does a gear pump operate to move oil?
Gears rotation captures oil at the inlet and transports it to the outlet where it is discharged into the outlet line.
Is there any explanation of the controls incorporated with the pump?
As stated on the data sheet the control system is fully automatic. To determine if this pump is appropriate for your application additional information is needed to evaluate the interface requirements with the control system.
What level of pressure does the pump need to generate to discharge the oil through the system?
The pump should be evaluated to determine if it can meet the required discharge pressure of the system it will be used in.
What is the flow rate, pressure and temperature of the oil to be pumped? What connection fittings and pipe sizes are needed? What power supply is available?
Are sanitation certifications required?
Provide your required flow rate and pressure of the oil to be pumped, the type and viscosity of the oil, operating temperature of the oil, and the space and power available for the pump. Based on this information we can suggest the appropriate gear pump to use in your application.
Contact us to discuss your edible oil pump requirements.
Check to see if a variable speed drive or pressure control valve is provided with the pump.
Low Pressure Service
Only pumps with ratings for low pressure service should be used for these applications. When selecting a pump verify that it will operate with the resistance in the system to develop the required discharge pressure.
Edible Oil Applications
Pumps in this service may be used to transfer edible oils from one location to another, or to supply oil to process equipment. When transferring oils factors such as the oil’s viscosity, length and elevation of the pipe run, and the presence of restrictions in the line must be considered to determine if the pump will provide sufficient flow for the application.
Configuration and Selection Considerations
Prior to purchase verify the type of oil to be transferred, viscosity, operating temperature, required flow and pressure, and the material of construction for the rotor and seals. Also determine the connections to be made to the inlet and outlet of the pump as well as the type and voltage of the electric motor to be used to drive the pump. For automatic control of the pump, determine the operation and control sequence to be utilized with the equipment to be integrated with the production process. Do not assume any food contact approvals or control components are included with the pump.
This configuration allows for the transfer of edible oils using an electrically controlled stainless steel pump. Other control components may also be required to integrate this pump with the user’s system. To avoid control and performance issues with the pump, user should supply additional information regarding the system with which the pump is to be integrated.
What oil is this pump designed to transfer?
Edible oils.
Verify the oil type and viscosity to confirm compatibility with the pump.
Also confirm operating temperature.
How does a gear pump operate to move oil?
Gears rotation captures oil at the inlet and transports it to the outlet where it is discharged into the outlet line.
Is there any explanation of the controls incorporated with the pump?
As stated on the data sheet the control system is fully automatic. To determine if this pump is appropriate for your application additional information is needed to evaluate the interface requirements with the control system.
What level of pressure does the pump need to generate to discharge the oil through the system?
The pump should be evaluated to determine if it can meet the required discharge pressure of the system it will be used in.
What is the flow rate, pressure and temperature of the oil to be pumped? What connection fittings and pipe sizes are needed? What power supply is available?
Are sanitation certifications required?
Provide your required flow rate and pressure of the oil to be pumped, the type and viscosity of the oil, operating temperature of the oil, and the space and power available for the pump. Based on this information we can suggest the appropriate gear pump to use in your application.
Contact us to discuss your edible oil pump requirements.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.