lobe pump common fault sorting here to see

It is not clear how much the big guys grasp about the stainless steel plate lobe pump manufacturer? The sludge lobe pump is based on the relative speed in the middle of the motor rotor and pump casing to work in the key for transporting these higher viscosity substances. It is not too large in volume, in addition to compact, and therefore holds a very critical influence at the industrial production level.

lobe pump

There are still more reasons that can cause excessive current in a sludge lobe pump, and I'm going to give you a brief detail of several of them here. The first thing you should do is to check the shaft or rolling bearing level problem to see if the rolling bearing has been damaged on a relative level, and if it has, it is proposed to save it immediately. If you can't save, you can carry out demolition and replacement for this matter. Secondly, the guys should check the lobe pump manufacturer's motor, the motor common fault will also cause the lobe pump manufacturer current amount is too high. Finally, we should put the vision to the inlet and outlet pipes, the inlet and outlet pipes if there is a hint of obstruction, then it will cause the inlet and outlet working pressure is getting very large. A large inlet and outlet working pressure, thus causing the expansion of the electric flow. In response to this type of situation, the guys just eliminate the blockage immediately.

lobe pump

What should I do if the sludge lobe pump does not have a total flow rate? The company's main goal is to provide a comprehensive range of products and services that are designed to meet the needs of the market. In accordance with common sense, the lobe pump manufacturer's rotational orientation is the key to the sludge lobe pump, and has a particularly important effect in keeping the sludge lobe pump working. If the rotational orientation of the lobe pump manufacturer is reversed, the lobe shaft sludge lobe pump will undoubtedly not be able to work properly and transport the material out. In this case, we have to adjust its orientation back quickly. Otherwise, it will damage the lobe pump manufacturer more seriously. Second, the guys can check the removal side pipe gate valve to see if they forget to open it. In addition, incidentally, check the suction side pipe gate valve. Whether the suction side pipeline gate valve is turned off or the discharge side pipeline gate valve is turned off, it is going to cause the lobe pump manufacturer no total flow.

lobe pump stoppage is a risky condition, which usually means that the sludge lobe pump's motor has encountered some obstruction, resulting in overpressure protection. In addition, if the inlet and outlet pressure is high, it can also cause this kind of condition to transform into. Secondly, we can see how the shaft and rolling bearing are sticking together, if the shaft and rolling bearing are stuck, the sludge lobe pump will also stop pumping.