Sanitary Stainless Steel Lobe Pump for Cream & Paste
$2,452.90 原价为:$2,452.90。$1,722.84当前价格为:$1,722.84。
We have a stainless steel cam rotor lobe pump for transferring high viscosity products like creams, pastes and toothpaste in processing and filling applications. Give us the viscosity of the product you are handling along with the flow and pressure requirements. Also give us the operating temperature of the product and the type of connection you will use, along with any requirements for cleaning the pump.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
Product Overview
Stainless steel cam rotor lobe pumps are used to transfer viscous products such as creams, pastes and liquids with high resistance to flow. An example of usage is to move product in a production line to process, store and fill. The pump described in this product bulletin is of sanitary design. Specific requirements of surface finish and compliance level should be specified prior to purchase.
Working Principle
In positive displacement pumps, two lobes mounted on the shaft of the pump rotate within the casing of the pump to capture product at the inlet and transport it to the outlet of the pump. With this design centrifugal force is not required to move the product through the pump as with some other designs. The rotation speed of the lobes should be adjusted to the viscosity of the product and the distance the product is required to be transported.
Key Features and Benefits
- Can be used to transfer viscous creams and pastes used in the manufacture of cosmetics
- Use of 316 stainless steel in the construction of the pump provides corrosion resistance
- Use of a cam rotor lobe design creates positive displacement to move the product through the system
- This design of pump can be cleaned to meet many of the requirements of sanitary applications. Check with us to confirm.
Applications
Examples of use include transporting creams and pastes within a production line to mix one component with another and transport the mixed product to storage prior to filling.
Slight variation in formulation or design could affect the performance of the pump. Thus, final assessment of suitability would require consideration to the formulation of the product to be pumped, the operating temperature and the piping layout.
Configuration and Technical Details
| Pump Type | Cam rotor lobe pump |
| Material of Construction | Stainless steel (unspecified grade) |
| Product to be Pumped | Cosmetic creams, pastes and toothpaste |
| Additional information | Flow rate, operating pressure and temperature |
| Seals, connections and controls | To be determined |
Reasons for Selection
Transfer of thick and viscous personal care products is often challenging. Therefore, many users find it convenient to incorporate a lobe pump in the transfer system to move the product within and between processing equipment. We can provide input on operating conditions to assist in choosing the correct material of construction for the pump’s seals to ensure compatibility with the product to be pumped.
How to Choose the Right Pump
Provide specifications of the product to be pumped including viscosity over the operating temperature range. Indicate the discharge pressure required, and the method to be employed for product removal and introduction to the system as well as any solids or gases which may be entrained with the product.
Most Frequent Questions
What kind of product can this lobe pump transfer?
Pump is designed to move pastes and creams of toothpaste and other cosmetic products.
How does this type of pump function?
Product is sucked into the pump through a series of lobes which transfer it to the outlet.
Is this pump appropriate for use in a cosmetic product manufacture?
Yes, to transfer creams and pastes.
Check the materials, finish and seals against your process requirements to determine if they will function effectively in your process. Also confirm the design meets your cleaning requirements.
What is the flow rate and operating pressure of the pump? These are important to define in order to confirm the pump will meet your process requirements.
To further define the application, is toothpaste to be dispensed with this system? Toothpaste is included in the product’s target media.
When requesting a quote for this product what information should be included? Include the working temperature, pressure and flow requirements of the medium to be pumped, as well as the connections and any other constraints of the system and the environment in which it will be installed. Also include any requirements for the material of construction of the system and any cleanliness requirements.
To initiate a Configuration Review, please contact us to provide the above information in addition to a process flow diagram. We will evaluate the pump and system requirements to provide a quote for transferring your cosmetic cream, paste or toothpaste.
Product Overview
Stainless steel cam rotor lobe pumps are used to transfer viscous products such as creams, pastes and liquids with high resistance to flow. An example of usage is to move product in a production line to process, store and fill. The pump described in this product bulletin is of sanitary design. Specific requirements of surface finish and compliance level should be specified prior to purchase.
Working Principle
In positive displacement pumps, two lobes mounted on the shaft of the pump rotate within the casing of the pump to capture product at the inlet and transport it to the outlet of the pump. With this design centrifugal force is not required to move the product through the pump as with some other designs. The rotation speed of the lobes should be adjusted to the viscosity of the product and the distance the product is required to be transported.
Key Features and Benefits
- Can be used to transfer viscous creams and pastes used in the manufacture of cosmetics
- Use of 316 stainless steel in the construction of the pump provides corrosion resistance
- Use of a cam rotor lobe design creates positive displacement to move the product through the system
- This design of pump can be cleaned to meet many of the requirements of sanitary applications. Check with us to confirm.
Applications
Examples of use include transporting creams and pastes within a production line to mix one component with another and transport the mixed product to storage prior to filling.
Slight variation in formulation or design could affect the performance of the pump. Thus, final assessment of suitability would require consideration to the formulation of the product to be pumped, the operating temperature and the piping layout.
Configuration and Technical Details
| Pump Type | Cam rotor lobe pump |
| Material of Construction | Stainless steel (unspecified grade) |
| Product to be Pumped | Cosmetic creams, pastes and toothpaste |
| Additional information | Flow rate, operating pressure and temperature |
| Seals, connections and controls | To be determined |
Reasons for Selection
Transfer of thick and viscous personal care products is often challenging. Therefore, many users find it convenient to incorporate a lobe pump in the transfer system to move the product within and between processing equipment. We can provide input on operating conditions to assist in choosing the correct material of construction for the pump’s seals to ensure compatibility with the product to be pumped.
How to Choose the Right Pump
Provide specifications of the product to be pumped including viscosity over the operating temperature range. Indicate the discharge pressure required, and the method to be employed for product removal and introduction to the system as well as any solids or gases which may be entrained with the product.
Most Frequent Questions
What kind of product can this lobe pump transfer?
Pump is designed to move pastes and creams of toothpaste and other cosmetic products.
How does this type of pump function?
Product is sucked into the pump through a series of lobes which transfer it to the outlet.
Is this pump appropriate for use in a cosmetic product manufacture?
Yes, to transfer creams and pastes.
Check the materials, finish and seals against your process requirements to determine if they will function effectively in your process. Also confirm the design meets your cleaning requirements.
What is the flow rate and operating pressure of the pump? These are important to define in order to confirm the pump will meet your process requirements.
To further define the application, is toothpaste to be dispensed with this system? Toothpaste is included in the product’s target media.
When requesting a quote for this product what information should be included? Include the working temperature, pressure and flow requirements of the medium to be pumped, as well as the connections and any other constraints of the system and the environment in which it will be installed. Also include any requirements for the material of construction of the system and any cleanliness requirements.
To initiate a Configuration Review, please contact us to provide the above information in addition to a process flow diagram. We will evaluate the pump and system requirements to provide a quote for transferring your cosmetic cream, paste or toothpaste.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.