Sanitary Stainless Steel Low-Shear Flexible Impeller Pump
$2,632.95 原价为:$2,632.95。$1,879.15当前价格为:$1,879.15。
We provide a stainless steel flexible impeller pump to evenly and gently transfer perishable liquids like dairy products, juice and beer. Known flow rates and available space of process connections also need to be considered when determining the best pump to use for the process.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
Sanitary Flexible Impeller Pump
Transfer of Perishable Foods and Beverages
This pump is constructed of stainless steel to facilitate the low shear transfer of juice, ketchup, beer and other food products. Each application requires careful consideration of the pump and pipe system to avoid problems such as foaming in the case of beer transfer or blockage in the case of ketchup transfer where a longer, larger diameter inlet may be needed.
Flexible Impeller
The flexible impeller is a positive displacement device where a rotor with elastomer vanes displaces product to the outlet of the pump. To withdraw product from the inlet of the pump, the vanes of the impeller must bend against the housing of the pump. Depending on the rate of rotation of the impeller and the pump size, the vacuum created on the inlet side of the impeller may be greater or less than the outlet, thus resulting in varying levels of product tautness.
Transfer of Foods and Beverages
Juice and Dairy
We suggest the use of this pump to transfer juice from one tank to another. To determine if this pump is also suitable to transfer dairy products, please provide the pressure and temperature of the dairy product to be transferred as well as the temperature of the wash water used to clean the line between transfers.
Transfer of Beer
When transferring beer between tanks, it is also important to determine the level of carbonation of the beer as well as the pressure in the system to avoid excessive foaming during the transfer process.
An airtight suction and line under pressure helps to keep the carbon dioxide dissolved in the beer. Let us know what type of beer you will be dispensing to assist us with determining the proper pump to use.
Transfer of thick sauces, such as ketchup, can also be problematic. When the system is first turned on to transfer ketchup from the batch tank to the hopper, the ketchup may not reach the impeller quickly enough and air may be drawn into the system. Therefore, we check to see if the pump will be able to maintain the flow of the ketchup using the actual arrangement of the inlet and the lowest temperature of the ketchup.
Technical Information and Product Description
| Motor | Flexible impeller |
| Sanitary stainless steel construction | Low shear transfer of food and beverage |
| Duties include transfer of dairy products, beer and juice | Other materials of construction to be determined |
| Port sizes, connection standards and orientation to be determined | Speed of the motor to be determined |
| Operating pressure and differential pressure to be determined | Foot print to be the same as the existing pump |
Prior to specifying a pump we require the following:
For systems that are used to transfer different products, we also have to take into account how the pump will be cleaned and the seals and impellers changed between transfers. Provide food contact certification of any wetted parts to be used in contact with the product. To replace the existing pump, provide the port dimensions, and orientations as well as the distance between them to help us verify that the new pump will fit. Give us the elevation of the discharge with respect to the location of the pump as well as the internal diameter of the piping and the pressure required at the receiving end to determine the pump size.
What are the minimum and maximum temperatures of the product handled by the pump? What viscosity of product does the pump handle? Does the supply tank have a flooded inlet? If a valve downstream of the pump can be closed while the pump is running, over pressure protection is recommended to be added to the system design.
Frequently Asked Questions
Is a flexible impeller pump a positive displacement pump?
Yes. The impeller has vanes which form pockets that draw product in and out of the impeller.
Can this pump transfer carbonated beer?
Carbonation in beer will come out of solution and be lost if the difference in pressure between the inlet and outlet of the pump is great enough to overcome the pressure in the beer.
What viscosity of ketchup needs to be pumped and what is the desired flow rate?
With these constraints we can select an appropriate model to ensure the difference in pressure across the pump is sufficient.
Can the flexible impeller pump be run dry?
Check the model you are using to determine its limits for running dry.
The impeller can be damaged from overheating if the pump is run dry. If the supply tank empties during use, this would be considered a process constraint to be incorporated in the specification.
Can the pump be cleaned in place?
We will evaluate clean in place suitability of the particular pump housing and seal configuration you have selected. To complete this assessment we would need more information on the cleaning solvent and the conditions of the clean in place cycle.
What food contact documents should be provided?
Provide the material specification and food contact certificates for the impeller and seals to be used in your application.
Based on the information provided above, what other constraints should be included in the quote for your application?
Request a Pump Quote
To provide a quote for a pump to use in your application, provide details of the fluid to be transferred, the transfer temperature and flow rate.
Sanitary Flexible Impeller Pump
Transfer of Perishable Foods and Beverages
This pump is constructed of stainless steel to facilitate the low shear transfer of juice, ketchup, beer and other food products. Each application requires careful consideration of the pump and pipe system to avoid problems such as foaming in the case of beer transfer or blockage in the case of ketchup transfer where a longer, larger diameter inlet may be needed.
Flexible Impeller
The flexible impeller is a positive displacement device where a rotor with elastomer vanes displaces product to the outlet of the pump. To withdraw product from the inlet of the pump, the vanes of the impeller must bend against the housing of the pump. Depending on the rate of rotation of the impeller and the pump size, the vacuum created on the inlet side of the impeller may be greater or less than the outlet, thus resulting in varying levels of product tautness.
Transfer of Foods and Beverages
Juice and Dairy
We suggest the use of this pump to transfer juice from one tank to another. To determine if this pump is also suitable to transfer dairy products, please provide the pressure and temperature of the dairy product to be transferred as well as the temperature of the wash water used to clean the line between transfers.
Transfer of Beer
When transferring beer between tanks, it is also important to determine the level of carbonation of the beer as well as the pressure in the system to avoid excessive foaming during the transfer process.
An airtight suction and line under pressure helps to keep the carbon dioxide dissolved in the beer. Let us know what type of beer you will be dispensing to assist us with determining the proper pump to use.
Transfer of thick sauces, such as ketchup, can also be problematic. When the system is first turned on to transfer ketchup from the batch tank to the hopper, the ketchup may not reach the impeller quickly enough and air may be drawn into the system. Therefore, we check to see if the pump will be able to maintain the flow of the ketchup using the actual arrangement of the inlet and the lowest temperature of the ketchup.
Technical Information and Product Description
| Motor | Flexible impeller |
| Sanitary stainless steel construction | Low shear transfer of food and beverage |
| Duties include transfer of dairy products, beer and juice | Other materials of construction to be determined |
| Port sizes, connection standards and orientation to be determined | Speed of the motor to be determined |
| Operating pressure and differential pressure to be determined | Foot print to be the same as the existing pump |
Prior to specifying a pump we require the following:
For systems that are used to transfer different products, we also have to take into account how the pump will be cleaned and the seals and impellers changed between transfers. Provide food contact certification of any wetted parts to be used in contact with the product. To replace the existing pump, provide the port dimensions, and orientations as well as the distance between them to help us verify that the new pump will fit. Give us the elevation of the discharge with respect to the location of the pump as well as the internal diameter of the piping and the pressure required at the receiving end to determine the pump size.
What are the minimum and maximum temperatures of the product handled by the pump? What viscosity of product does the pump handle? Does the supply tank have a flooded inlet? If a valve downstream of the pump can be closed while the pump is running, over pressure protection is recommended to be added to the system design.
Frequently Asked Questions
Is a flexible impeller pump a positive displacement pump?
Yes. The impeller has vanes which form pockets that draw product in and out of the impeller.
Can this pump transfer carbonated beer?
Carbonation in beer will come out of solution and be lost if the difference in pressure between the inlet and outlet of the pump is great enough to overcome the pressure in the beer.
What viscosity of ketchup needs to be pumped and what is the desired flow rate?
With these constraints we can select an appropriate model to ensure the difference in pressure across the pump is sufficient.
Can the flexible impeller pump be run dry?
Check the model you are using to determine its limits for running dry.
The impeller can be damaged from overheating if the pump is run dry. If the supply tank empties during use, this would be considered a process constraint to be incorporated in the specification.
Can the pump be cleaned in place?
We will evaluate clean in place suitability of the particular pump housing and seal configuration you have selected. To complete this assessment we would need more information on the cleaning solvent and the conditions of the clean in place cycle.
What food contact documents should be provided?
Provide the material specification and food contact certificates for the impeller and seals to be used in your application.
Based on the information provided above, what other constraints should be included in the quote for your application?
Request a Pump Quote
To provide a quote for a pump to use in your application, provide details of the fluid to be transferred, the transfer temperature and flow rate.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.