Stainless Steel Food-Grade Rotary Lobe Pump
$2,448.42 原价为:$2,448.42。$1,740.99当前价格为:$1,740.99。
Our stainless steel rotary lobe pump is food safe and can be used to move honey, ice cream mix and other similar products between tanks, processing equipment and packaging lines. We will work with you to specify the pump to best fit with your process taking into account the viscosity, operating temperature and the flow and pressure requirements of your system.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
We also consider overpressure protection for lines containing shutoff valves or filling equipment.
Food Processing
Transfer of Ice Cream Mix
The viscosity of the ice cream mix determines the size of the pump to transfer the mix from the aging tank to the freezer feed system. Aerated or partially frozen ice cream may require review of overrun to determine the shear that the pump may introduce to the product.
Transfer pumps for honey need to be larger to account for the higher viscosity of the honey at lower temperatures. Crystallization of honey may increase the startup torque required to initiate flow to the pump.
Pumps used to transfer chocolate from a holding tank to a depositor or enrober need to be insulated to retain the liquid in a fluid state. If the line is allowed to cool between each batch of chocolate, a heat tracing system may be incorporated in the line to keep the chocolate fluid.
Configuration and Technical Details
A rotary lobe positive displacement pump is to be used for transfer of liquid to and from the food processing equipment. The pump and other accessories in contact with the product must be constructed of stainless steel of the appropriate alloy and finish. Pumps must be sized for the viscosity and temperature of the product to be transferred. Seals and elastomers must also be compatible with the product.
What is the speed range of the electric motor? What type of electrical connection will be used?
How do we size the pump?
We take into account the flow rate and the pressure difference across the pump for each product through the temperature range for which the product is being processed. Length of pipeline, diameter of pipeline, and restrictions in the system determine whether the pump can provide the desired flow rate. For systems which start with product in the piping, we size the gear motor and pump accordingly.
What is the procedure to clean and service the pump?
The answers to these questions determine the size of the motor and gear assembly required. Knowing these answers before ordering the pump can prevent the need to modify the piping during installation.
Is one rotary lobe pump sufficient to transfer both honey and chocolate?
To answer this question we would need to understand the operating conditions of both products as well as the procedures in place to clean the equipment to prevent cross contamination.
What information do you need to determine the size of a pump to transfer cold honey?
Preferably the lowest temperature honey is expected to be processed at, the viscosity of the honey at this temperature, the flow rate required and the size of the outlet of the honey tank.
Could this pump be used to transfer ice cream after it has been frozen?
Aerated products generally require a larger pump than liquid products.
Product characteristics such as temperature, air content and texture determine the appropriate configuration of rotor and drive.
Do chocolate transfer pumps require a heating jacket?
This depends on the temperature of the chocolate being transferred and the ambient temperature around the pump. If the chocolate is temperature sensitive and could solidify during transfer, then a heating jacket would be used to surround the pump and maintain the chocolate at transfer temperature.
Is the pump design amenable to clean in place?
We would have to evaluate the cleaning solution, flow rate and temperature to ensure the pump and associated seals can withstand the cleaning condition. We also need to assess which components need to be accessible for inspection and service.
What type of documentation should I request to confirm the pump contacting food is of appropriate quality?
The user of the pump should specify the requirements for the metals in contact with food, the surface finish of the elastomers as well as any relevant sanitary standards.
Request a quote for a food transfer pump
To provide a quote for a food transfer pump, we need to understand the properties of the product to be transferred, the flow rate and temperature range of the product to be transferred, the viscosity of the product as well as the layout of the transfer piping.
We also consider overpressure protection for lines containing shutoff valves or filling equipment.
Food Processing
Transfer of Ice Cream Mix
The viscosity of the ice cream mix determines the size of the pump to transfer the mix from the aging tank to the freezer feed system. Aerated or partially frozen ice cream may require review of overrun to determine the shear that the pump may introduce to the product.
Transfer pumps for honey need to be larger to account for the higher viscosity of the honey at lower temperatures. Crystallization of honey may increase the startup torque required to initiate flow to the pump.
Pumps used to transfer chocolate from a holding tank to a depositor or enrober need to be insulated to retain the liquid in a fluid state. If the line is allowed to cool between each batch of chocolate, a heat tracing system may be incorporated in the line to keep the chocolate fluid.
Configuration and Technical Details
A rotary lobe positive displacement pump is to be used for transfer of liquid to and from the food processing equipment. The pump and other accessories in contact with the product must be constructed of stainless steel of the appropriate alloy and finish. Pumps must be sized for the viscosity and temperature of the product to be transferred. Seals and elastomers must also be compatible with the product.
What is the speed range of the electric motor? What type of electrical connection will be used?
How do we size the pump?
We take into account the flow rate and the pressure difference across the pump for each product through the temperature range for which the product is being processed. Length of pipeline, diameter of pipeline, and restrictions in the system determine whether the pump can provide the desired flow rate. For systems which start with product in the piping, we size the gear motor and pump accordingly.
What is the procedure to clean and service the pump?
The answers to these questions determine the size of the motor and gear assembly required. Knowing these answers before ordering the pump can prevent the need to modify the piping during installation.
Is one rotary lobe pump sufficient to transfer both honey and chocolate?
To answer this question we would need to understand the operating conditions of both products as well as the procedures in place to clean the equipment to prevent cross contamination.
What information do you need to determine the size of a pump to transfer cold honey?
Preferably the lowest temperature honey is expected to be processed at, the viscosity of the honey at this temperature, the flow rate required and the size of the outlet of the honey tank.
Could this pump be used to transfer ice cream after it has been frozen?
Aerated products generally require a larger pump than liquid products.
Product characteristics such as temperature, air content and texture determine the appropriate configuration of rotor and drive.
Do chocolate transfer pumps require a heating jacket?
This depends on the temperature of the chocolate being transferred and the ambient temperature around the pump. If the chocolate is temperature sensitive and could solidify during transfer, then a heating jacket would be used to surround the pump and maintain the chocolate at transfer temperature.
Is the pump design amenable to clean in place?
We would have to evaluate the cleaning solution, flow rate and temperature to ensure the pump and associated seals can withstand the cleaning condition. We also need to assess which components need to be accessible for inspection and service.
What type of documentation should I request to confirm the pump contacting food is of appropriate quality?
The user of the pump should specify the requirements for the metals in contact with food, the surface finish of the elastomers as well as any relevant sanitary standards.
Request a quote for a food transfer pump
To provide a quote for a food transfer pump, we need to understand the properties of the product to be transferred, the flow rate and temperature range of the product to be transferred, the viscosity of the product as well as the layout of the transfer piping.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.