2.2 kW 316L Sanitary Lobe Pump for Cream and Chocolate
$2,066.55 原价为:$2,066.55。$1,512.37当前价格为:$1,512.37。
Our 2.2 kW sanitary lobe pump with 316L stainless steel construction, 400 V 50 Hz motor and fixed ratio gearbox is appropriate for transferring dairy cream or liquid chocolate from a holding tank to, for example, a blending machine, hopper or depositor.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
We use the actual reduction ratio and rotor speed to calculate the ‘duty point’ to ensure the 2.2 kW motor will handle the process load and torque requirement.
Dairy Plants
Transfer of Cream
This pump may be used to transfer cream from a refrigerated storage tank to a blending tank or to a fill hopper feeding a packaging machine. To avoid suction loss in the pipe, the inlet to the pump should be as short as practical to minimize air entrainment which can cause frothing of the product.
Transfer of Chocolate
This pump may also be used to transfer liquid chocolate to a depositing machine. Chocolate may thicken and stick to the walls of the pipe. If chocolate has built up on the sides of the pipe it may need to be removed prior to transfer.
Product Data and Specifications
| Type: | Sanitary rotary lobe pump |
| Construction: | Stainless steel 316L |
| Motor power: | 2.2 kW |
| Voltage: | 400 V at 50 Hz |
| Speed of rotation: | variable with gear box |
| Media to be pumped: | Cream or liquid chocolate |
During the quotation process we verify many factors to determine if this pump will satisfy the customer’s requirement. These factors include the material of construction of components in contact with the product, surface finish, rotation speed of the rotors, gear box ratio, dimensions and standards of inlet and outlet connections. We also assess the cleaning and maintenance requirements of the pump to determine if the pump will fit in the available space in the plant.
Check the voltage and phase of the site power supply before ordering. Some facilities operate at 60 Hz.
This pump should be evaluated to transfer product between two fixed points on a conveyor line. On a filler feed line, the pump should be coordinated to start along with the filler to control the level of product in the hopper. To plan maintenance of the filler, the pump should also be stopped to remove the product from the hopper.
To determine the size pump to move product along the conveyor line, inform us of the flow rate, discharge elevation, length and diameter of the conveying line and the back pressure of equipment at the discharge. Also provide the viscosity of the product to be conveyed at the transfer temperature as well as at the lowest temperature at which it may be revolved. Indicate the lowest level to which the source tank may be drawn down to and the arrangement of the inlet to the pump to ensure adequate suction. Lastly, tell us the standards of the product to be conveyed and the cleaning method to be performed on the pump.
What type of electrical control will be used to start and stop the pump?
Can the same pump be used to transfer both liquid chocolate and dairy cream?
Generally speaking yes, although depending on the product and conveying conditions, a set of tests may have to be performed to validate that the pump can meet the transfer requirements for both products.
We also look at procedures to clean and change allergens for shared lines.
What flow rate can the 2.2 kW lobe pump achieve?
To answer this we take into account viscosity of the product being transferred and existing differences in pressure in the system. Send us the flow rate you are hoping to achieve, along with the length of the transfer line to perform a duty point analysis.
Is it possible to change the speed of the ratio drive?
No. The mechanical ratio is fixed. To change the speed of the pump you would need to also vary the speed of the motor, using a variable frequency drive for example. We can verify if the motor can operate across the speed and torque range required to perform this function.
Would a transfer line for chocolate require a heated pump head?
This would depend on how much heat is lost from the product during transport and at stops on the line.
To determine if a jacketed pump head is required, we assess the minimum acceptable product temperature, idle time and restart conditions.
Is the sanitary lobe pump quoted suitable for clean in place duty?
Prior to providing an answer to this question we assess the type of seal employed, internal geometry of the pump, whether drainability exists in the installed position, and the characteristics of the cleaning cycle employed.
Is it acceptable to use the motors with 60 Hz supply?
We will need to verify the motor nameplate with the drive employed to ascertain if the motor is suitable to be used at 60 Hz.
What are the flow and temperature of the product to be transported? What are the process connections? What power is available on site?
Based on the information provided, we will perform a preliminary assessment of your ‘duty point’ and quote the most appropriate pump and associated drive to transport your product.
We use the actual reduction ratio and rotor speed to calculate the ‘duty point’ to ensure the 2.2 kW motor will handle the process load and torque requirement.
Dairy Plants
Transfer of Cream
This pump may be used to transfer cream from a refrigerated storage tank to a blending tank or to a fill hopper feeding a packaging machine. To avoid suction loss in the pipe, the inlet to the pump should be as short as practical to minimize air entrainment which can cause frothing of the product.
Transfer of Chocolate
This pump may also be used to transfer liquid chocolate to a depositing machine. Chocolate may thicken and stick to the walls of the pipe. If chocolate has built up on the sides of the pipe it may need to be removed prior to transfer.
Product Data and Specifications
| Type: | Sanitary rotary lobe pump |
| Construction: | Stainless steel 316L |
| Motor power: | 2.2 kW |
| Voltage: | 400 V at 50 Hz |
| Speed of rotation: | variable with gear box |
| Media to be pumped: | Cream or liquid chocolate |
During the quotation process we verify many factors to determine if this pump will satisfy the customer’s requirement. These factors include the material of construction of components in contact with the product, surface finish, rotation speed of the rotors, gear box ratio, dimensions and standards of inlet and outlet connections. We also assess the cleaning and maintenance requirements of the pump to determine if the pump will fit in the available space in the plant.
Check the voltage and phase of the site power supply before ordering. Some facilities operate at 60 Hz.
This pump should be evaluated to transfer product between two fixed points on a conveyor line. On a filler feed line, the pump should be coordinated to start along with the filler to control the level of product in the hopper. To plan maintenance of the filler, the pump should also be stopped to remove the product from the hopper.
To determine the size pump to move product along the conveyor line, inform us of the flow rate, discharge elevation, length and diameter of the conveying line and the back pressure of equipment at the discharge. Also provide the viscosity of the product to be conveyed at the transfer temperature as well as at the lowest temperature at which it may be revolved. Indicate the lowest level to which the source tank may be drawn down to and the arrangement of the inlet to the pump to ensure adequate suction. Lastly, tell us the standards of the product to be conveyed and the cleaning method to be performed on the pump.
What type of electrical control will be used to start and stop the pump?
Can the same pump be used to transfer both liquid chocolate and dairy cream?
Generally speaking yes, although depending on the product and conveying conditions, a set of tests may have to be performed to validate that the pump can meet the transfer requirements for both products.
We also look at procedures to clean and change allergens for shared lines.
What flow rate can the 2.2 kW lobe pump achieve?
To answer this we take into account viscosity of the product being transferred and existing differences in pressure in the system. Send us the flow rate you are hoping to achieve, along with the length of the transfer line to perform a duty point analysis.
Is it possible to change the speed of the ratio drive?
No. The mechanical ratio is fixed. To change the speed of the pump you would need to also vary the speed of the motor, using a variable frequency drive for example. We can verify if the motor can operate across the speed and torque range required to perform this function.
Would a transfer line for chocolate require a heated pump head?
This would depend on how much heat is lost from the product during transport and at stops on the line.
To determine if a jacketed pump head is required, we assess the minimum acceptable product temperature, idle time and restart conditions.
Is the sanitary lobe pump quoted suitable for clean in place duty?
Prior to providing an answer to this question we assess the type of seal employed, internal geometry of the pump, whether drainability exists in the installed position, and the characteristics of the cleaning cycle employed.
Is it acceptable to use the motors with 60 Hz supply?
We will need to verify the motor nameplate with the drive employed to ascertain if the motor is suitable to be used at 60 Hz.
What are the flow and temperature of the product to be transported? What are the process connections? What power is available on site?
Based on the information provided, we will perform a preliminary assessment of your ‘duty point’ and quote the most appropriate pump and associated drive to transport your product.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.