2.2 kW 50Hz 316L Jacketed Honey Rotary Lobe Pump
2.2 kW 50Hz 316L Jacketed Honey Rotary Lobe Pump 原价为:$2,429.58。当前价格为:$1,708.80。
返回产品
2.2 kW Stainless Steel Rotary Lobe Pump for High-Viscosity Fluids
2.2 kW Stainless Steel Rotary Lobe Pump for High-Viscosity Fluids 原价为:$2,438.98。当前价格为:$1,664.87。

2.2 kW 316L Sanitary Lobe Pump for Cream and Chocolate

原价为:$2,066.55。当前价格为:$1,512.37。

Our 2.2 kW sanitary lobe pump with 316L stainless steel construction, 400 V 50 Hz motor and fixed ratio gearbox is appropriate for transferring dairy cream or liquid chocolate from a holding tank to, for example, a blending machine, hopper or depositor.

库存 100 件

Rotor Optional

Three-Lobe Rotor

Applicable Liquids:

  • Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
  • Example: Chocolate, honey, mashed potatoes and ice cream.
Three-Lobe Rotor

Butterfly Rotor

Applicable Liquids:

  • Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
  • Example: Jam, pulp, juice, jelly and tomato sauce.
Butterfly Rotor

Single-Lobe Rotor

Applicable Liquids:

  • Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
  • Example: Rock salt, chilli sauce and peanut butter.
Single-Lobe Rotor

Multi-Lobe Rotor

Applicable Liquids:

  • Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
  • Example: Chocolate, honey, cream, yoghurt, butter and grease.
Multi-Lobe Rotor

Parameter Chart

lobe pump Parameter Chart
← Swipe left or right to view all specifications →
Model Flow per
100 Rotation
Power
(kW)
Suggested
RPM
Capacity
(L/H)
Diameter L H H1 W W1 Connection Type
ZB3A-3 3L 0.55 200-500 300-800 Φ25×1.5 710 290 150 150 240 Clamp / Thread / Flange
ZB3A-6 6L 0.75 200-500 650-1600 Φ25×1.5 780 390 170 190 240 Clamp / Thread / Flange
ZB3A-8 8L 1.5 200-500 850-2160 Φ38×1.5 850 400 170 190 280 Clamp / Thread / Flange
ZB3A-12 12L 2.2 200-500 1300-3200 Φ38×1.5 980 450 185 220 330 Clamp / Thread / Flange
ZB3A-20 20L 3 200-500 2100-5400 Φ38×1.5 1000 450 190 250 330 Clamp / Thread / Flange
ZB3A-30 30L 4 200-500 3200-6400 Φ50.8×1.5 1050 480 220 270 350 Clamp / Thread / Flange
ZB3A-36 36L 4 200-400 3800-7600 Φ50.8×1.5 1100 490 220 270 360 Clamp / Thread / Flange
ZB3A-52 52L 5.5 200-400 5600-11000 Φ63×1.5 1250 580 260 270 480 Clamp / Thread / Flange
ZB3A-66 66L 7.5 200-400 7100-14000 Φ76×1.5 1350 600 260 270 480 Clamp / Thread / Flange
ZB3A-78 78L 7.5 200-400 9000-18000 Φ76×1.5 1260 600 295 370 480 Clamp / Thread / Flange
ZB3A-100 100L 11 200-400 11000-22000 Φ76×2 1320 670 295 370 480 Clamp / Thread / Flange
ZB3A-135 135L 15 200-400 15000-30000 Φ89×2 1500 670 295 370 480 Clamp / Thread / Flange
ZB3A-160 160L 18.5 200-400 17000-34000 Φ102×3 1500 720 320 420 560 Clamp / Thread / Flange
ZB3A-200 200L 22 200-400 21600-43000 Φ102×3 1500 720 320 420 560 Clamp / Thread / Flange
ZB3A-300 300L 30 200-400 32400-64800 Φ125×3 1650 800 400 480 620 Clamp / Thread / Flange
ZB3A-400 400L 37 200-400 43200-86400 Φ150×3 1700 800 400 480 620 Clamp / Thread / Flange
Dimensions are shown as L / H / H1 / W / W1. On mobile, you can swipe horizontally to view the full table.

We use the actual reduction ratio and rotor speed to calculate the ‘duty point’ to ensure the 2.2 kW motor will handle the process load and torque requirement.

Dairy Plants

Transfer of Cream

This pump may be used to transfer cream from a refrigerated storage tank to a blending tank or to a fill hopper feeding a packaging machine. To avoid suction loss in the pipe, the inlet to the pump should be as short as practical to minimize air entrainment which can cause frothing of the product.

Transfer of Chocolate

This pump may also be used to transfer liquid chocolate to a depositing machine. Chocolate may thicken and stick to the walls of the pipe. If chocolate has built up on the sides of the pipe it may need to be removed prior to transfer.

Product Data and Specifications

Type: Sanitary rotary lobe pump
Construction: Stainless steel 316L
Motor power: 2.2 kW
Voltage: 400 V at 50 Hz
Speed of rotation: variable with gear box
Media to be pumped: Cream or liquid chocolate

During the quotation process we verify many factors to determine if this pump will satisfy the customer’s requirement. These factors include the material of construction of components in contact with the product, surface finish, rotation speed of the rotors, gear box ratio, dimensions and standards of inlet and outlet connections. We also assess the cleaning and maintenance requirements of the pump to determine if the pump will fit in the available space in the plant.

Check the voltage and phase of the site power supply before ordering. Some facilities operate at 60 Hz.

This pump should be evaluated to transfer product between two fixed points on a conveyor line. On a filler feed line, the pump should be coordinated to start along with the filler to control the level of product in the hopper. To plan maintenance of the filler, the pump should also be stopped to remove the product from the hopper.

To determine the size pump to move product along the conveyor line, inform us of the flow rate, discharge elevation, length and diameter of the conveying line and the back pressure of equipment at the discharge. Also provide the viscosity of the product to be conveyed at the transfer temperature as well as at the lowest temperature at which it may be revolved. Indicate the lowest level to which the source tank may be drawn down to and the arrangement of the inlet to the pump to ensure adequate suction. Lastly, tell us the standards of the product to be conveyed and the cleaning method to be performed on the pump.

What type of electrical control will be used to start and stop the pump?

Can the same pump be used to transfer both liquid chocolate and dairy cream?

Generally speaking yes, although depending on the product and conveying conditions, a set of tests may have to be performed to validate that the pump can meet the transfer requirements for both products.

We also look at procedures to clean and change allergens for shared lines.

What flow rate can the 2.2 kW lobe pump achieve?

To answer this we take into account viscosity of the product being transferred and existing differences in pressure in the system. Send us the flow rate you are hoping to achieve, along with the length of the transfer line to perform a duty point analysis.

Is it possible to change the speed of the ratio drive?

No. The mechanical ratio is fixed. To change the speed of the pump you would need to also vary the speed of the motor, using a variable frequency drive for example. We can verify if the motor can operate across the speed and torque range required to perform this function.

Would a transfer line for chocolate require a heated pump head?

This would depend on how much heat is lost from the product during transport and at stops on the line.

To determine if a jacketed pump head is required, we assess the minimum acceptable product temperature, idle time and restart conditions.

Is the sanitary lobe pump quoted suitable for clean in place duty?

Prior to providing an answer to this question we assess the type of seal employed, internal geometry of the pump, whether drainability exists in the installed position, and the characteristics of the cleaning cycle employed.

Is it acceptable to use the motors with 60 Hz supply?

We will need to verify the motor nameplate with the drive employed to ascertain if the motor is suitable to be used at 60 Hz.

What are the flow and temperature of the product to be transported? What are the process connections? What power is available on site?

Based on the information provided, we will perform a preliminary assessment of your ‘duty point’ and quote the most appropriate pump and associated drive to transport your product.

描述

We use the actual reduction ratio and rotor speed to calculate the ‘duty point’ to ensure the 2.2 kW motor will handle the process load and torque requirement.

Dairy Plants

Transfer of Cream

This pump may be used to transfer cream from a refrigerated storage tank to a blending tank or to a fill hopper feeding a packaging machine. To avoid suction loss in the pipe, the inlet to the pump should be as short as practical to minimize air entrainment which can cause frothing of the product.

Transfer of Chocolate

This pump may also be used to transfer liquid chocolate to a depositing machine. Chocolate may thicken and stick to the walls of the pipe. If chocolate has built up on the sides of the pipe it may need to be removed prior to transfer.

Product Data and Specifications

Type: Sanitary rotary lobe pump
Construction: Stainless steel 316L
Motor power: 2.2 kW
Voltage: 400 V at 50 Hz
Speed of rotation: variable with gear box
Media to be pumped: Cream or liquid chocolate

During the quotation process we verify many factors to determine if this pump will satisfy the customer’s requirement. These factors include the material of construction of components in contact with the product, surface finish, rotation speed of the rotors, gear box ratio, dimensions and standards of inlet and outlet connections. We also assess the cleaning and maintenance requirements of the pump to determine if the pump will fit in the available space in the plant.

Check the voltage and phase of the site power supply before ordering. Some facilities operate at 60 Hz.

This pump should be evaluated to transfer product between two fixed points on a conveyor line. On a filler feed line, the pump should be coordinated to start along with the filler to control the level of product in the hopper. To plan maintenance of the filler, the pump should also be stopped to remove the product from the hopper.

To determine the size pump to move product along the conveyor line, inform us of the flow rate, discharge elevation, length and diameter of the conveying line and the back pressure of equipment at the discharge. Also provide the viscosity of the product to be conveyed at the transfer temperature as well as at the lowest temperature at which it may be revolved. Indicate the lowest level to which the source tank may be drawn down to and the arrangement of the inlet to the pump to ensure adequate suction. Lastly, tell us the standards of the product to be conveyed and the cleaning method to be performed on the pump.

What type of electrical control will be used to start and stop the pump?

Can the same pump be used to transfer both liquid chocolate and dairy cream?

Generally speaking yes, although depending on the product and conveying conditions, a set of tests may have to be performed to validate that the pump can meet the transfer requirements for both products.

We also look at procedures to clean and change allergens for shared lines.

What flow rate can the 2.2 kW lobe pump achieve?

To answer this we take into account viscosity of the product being transferred and existing differences in pressure in the system. Send us the flow rate you are hoping to achieve, along with the length of the transfer line to perform a duty point analysis.

Is it possible to change the speed of the ratio drive?

No. The mechanical ratio is fixed. To change the speed of the pump you would need to also vary the speed of the motor, using a variable frequency drive for example. We can verify if the motor can operate across the speed and torque range required to perform this function.

Would a transfer line for chocolate require a heated pump head?

This would depend on how much heat is lost from the product during transport and at stops on the line.

To determine if a jacketed pump head is required, we assess the minimum acceptable product temperature, idle time and restart conditions.

Is the sanitary lobe pump quoted suitable for clean in place duty?

Prior to providing an answer to this question we assess the type of seal employed, internal geometry of the pump, whether drainability exists in the installed position, and the characteristics of the cleaning cycle employed.

Is it acceptable to use the motors with 60 Hz supply?

We will need to verify the motor nameplate with the drive employed to ascertain if the motor is suitable to be used at 60 Hz.

What are the flow and temperature of the product to be transported? What are the process connections? What power is available on site?

Based on the information provided, we will perform a preliminary assessment of your ‘duty point’ and quote the most appropriate pump and associated drive to transport your product.

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.