Tomato Paste Rotary Lobe Pump with Hopper & Inverter
$2,720.94 原价为:$2,720.94。$1,975.86当前价格为:$1,975.86。
We supply a sanitary rotary lobe pump transports tomato paste and is offered with a hopper trolley, inverter and control cabinet. Provide the flow rate and operating pressure of the paste along with the physical properties of the product to enable us to verify that the pump will be adequate for your application.
库存 100 件
Rotor Optional
Three-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity, uniform texture and no hard granules.
- Example: Chocolate, honey, mashed potatoes and ice cream.
Butterfly Rotor
Applicable Liquids:
- Suitable for shear-free, non-destructive transfer of soft-grained sauces and small-particle materials.
- Example: Jam, pulp, juice, jelly and tomato sauce.
Single-Lobe Rotor
Applicable Liquids:
- Suitable for conveying materials containing larger solid particles while maintaining stable transfer.
- Example: Rock salt, chilli sauce and peanut butter.
Multi-Lobe Rotor
Applicable Liquids:
- Suitable for creams, liquids and sauces with low, medium and high viscosity where higher output accuracy and smooth flow are required.
- Example: Chocolate, honey, cream, yoghurt, butter and grease.
Parameter Chart
| Model | Flow per 100 Rotation |
Power (kW) |
Suggested RPM |
Capacity (L/H) |
Diameter | L | H | H1 | W | W1 | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZB3A-3 | 3L | 0.55 | 200-500 | 300-800 | Φ25×1.5 | 710 | 290 | 150 | 150 | 240 | Clamp / Thread / Flange |
| ZB3A-6 | 6L | 0.75 | 200-500 | 650-1600 | Φ25×1.5 | 780 | 390 | 170 | 190 | 240 | Clamp / Thread / Flange |
| ZB3A-8 | 8L | 1.5 | 200-500 | 850-2160 | Φ38×1.5 | 850 | 400 | 170 | 190 | 280 | Clamp / Thread / Flange |
| ZB3A-12 | 12L | 2.2 | 200-500 | 1300-3200 | Φ38×1.5 | 980 | 450 | 185 | 220 | 330 | Clamp / Thread / Flange |
| ZB3A-20 | 20L | 3 | 200-500 | 2100-5400 | Φ38×1.5 | 1000 | 450 | 190 | 250 | 330 | Clamp / Thread / Flange |
| ZB3A-30 | 30L | 4 | 200-500 | 3200-6400 | Φ50.8×1.5 | 1050 | 480 | 220 | 270 | 350 | Clamp / Thread / Flange |
| ZB3A-36 | 36L | 4 | 200-400 | 3800-7600 | Φ50.8×1.5 | 1100 | 490 | 220 | 270 | 360 | Clamp / Thread / Flange |
| ZB3A-52 | 52L | 5.5 | 200-400 | 5600-11000 | Φ63×1.5 | 1250 | 580 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-66 | 66L | 7.5 | 200-400 | 7100-14000 | Φ76×1.5 | 1350 | 600 | 260 | 270 | 480 | Clamp / Thread / Flange |
| ZB3A-78 | 78L | 7.5 | 200-400 | 9000-18000 | Φ76×1.5 | 1260 | 600 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-100 | 100L | 11 | 200-400 | 11000-22000 | Φ76×2 | 1320 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-135 | 135L | 15 | 200-400 | 15000-30000 | Φ89×2 | 1500 | 670 | 295 | 370 | 480 | Clamp / Thread / Flange |
| ZB3A-160 | 160L | 18.5 | 200-400 | 17000-34000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-200 | 200L | 22 | 200-400 | 21600-43000 | Φ102×3 | 1500 | 720 | 320 | 420 | 560 | Clamp / Thread / Flange |
| ZB3A-300 | 300L | 30 | 200-400 | 32400-64800 | Φ125×3 | 1650 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
| ZB3A-400 | 400L | 37 | 200-400 | 43200-86400 | Φ150×3 | 1700 | 800 | 400 | 480 | 620 | Clamp / Thread / Flange |
Sanitary Rotary Lobe Pump for Tomato Paste
The rotary lobe pump in this package is designed to move tomato paste along with a hopper trolley and control cabinet. It is to be used to transport tomato paste from one location to another in a food processing plant. Within the designated limit of the design the user should confirm the specific requirements for capacity, pressure and connections for their application.
Operation
Tomato paste to be transported is drawn into the pump by lobes which rotate inside the casing of the pump and then discharged through an outlet on the other end of the casing. The lobes of the rotor do not touch each other during operation. To facilitate transfer of the paste to the outlet the system should not be run empty.
The hopper located on the trolley provides a means to load the pump and to move the equipment to other locations on the plant floor. The control of pump speed is accomplished with the inverter which is mounted in the control cabinet along with other controls. Check with the supplier to confirm operation of the controls and the electrical specifications that will be used in your plant.
Features
Tomato paste is moved by a positive displacement rotary lobe pump. A hopper is provided to load the paste into the system. The complete unit is transportable on a trolley.
Speed control of the inverter allows adjustment of the pump’s speed to best suit process requirements, as long as it remains within the approved limits.
The control cabinet provides enclosure to house the controls and wiring. Customer should verify the components and connection types prior to ordering.
Sanitary design of the pump allows it to come in contact with foods and ingredients. Customer should evaluate the material of contact with the product to determine its suitability.
The applications of this configuration are to transfer tomato paste to and from various stages of the tomato processing and filling line. Tomato paste can vary in viscosity and contain particles. Therefore, it is important to understand the characteristics of the product being transferred to select the proper pump for the application.
The title of the literature describes a sanitary, variable speed rotary lobe pump with a hopper trolley and control cabinet. Further details on the internal components of the pump are lacking. Customer should verify these with the supplier prior to purchase.
Information needed to evaluate the suitability of the pump for a given application includes the flow rate and discharge pressure required, temperature and viscosity of the tomato paste, parts of the paste, if any, suspended in the paste, the frequency with which the pump is to be operated to transport the paste, the electrical service available at the location of installation.
This may assist the production team to position and attach the equipment to the process equipment. Check the trolley to determine its mobility and the functions of the control panel to be used in operation and to clean the equipment.
Frequently Asked Questions
What does the rotary lobe pump transfer?
This pump is to transfer tomato paste. Check to see if the paste contains any solids and verify the viscosity and temperature of the paste.
How does the rotary lobe pump operate?
The lobe of the pump creates a cavity which vacuum draws the product into the pump and pushes it to the outlet of the pump.
What is the function of the hopper trolley?
The hopper collects product to be transferred to the pump. Determine the dimensions to see if it will fit in the space available in your facility.
Will changing the speed of the inverter change the flow rate of the pump?
Yes. The inverter alters the speed of the impeller of the pump to some extent, thus adjusting the flow rate to some degree, based on the requirements of the system.
What should I verify prior to purchasing this product?
Verify the required flow and pressure of the system, power requirement of the motor, materials in contact with the product, connections, and the method of electrical supply. Also determine the frequency with which the equipment needs to be cleaned.
Can I use this pump for cleaning in place?
The pump can be used for CIP; however, for what purposes and with what frequency it should be cleaned must be determined. Consult the manufacturer for these details.
Request a Quote
To obtain a quotation, provide us with the physical properties of the tomato paste to be transferred, the flow rate and pressure required, and the electrical specifications of the equipment.
Sanitary Rotary Lobe Pump for Tomato Paste
The rotary lobe pump in this package is designed to move tomato paste along with a hopper trolley and control cabinet. It is to be used to transport tomato paste from one location to another in a food processing plant. Within the designated limit of the design the user should confirm the specific requirements for capacity, pressure and connections for their application.
Operation
Tomato paste to be transported is drawn into the pump by lobes which rotate inside the casing of the pump and then discharged through an outlet on the other end of the casing. The lobes of the rotor do not touch each other during operation. To facilitate transfer of the paste to the outlet the system should not be run empty.
The hopper located on the trolley provides a means to load the pump and to move the equipment to other locations on the plant floor. The control of pump speed is accomplished with the inverter which is mounted in the control cabinet along with other controls. Check with the supplier to confirm operation of the controls and the electrical specifications that will be used in your plant.
Features
Tomato paste is moved by a positive displacement rotary lobe pump. A hopper is provided to load the paste into the system. The complete unit is transportable on a trolley.
Speed control of the inverter allows adjustment of the pump’s speed to best suit process requirements, as long as it remains within the approved limits.
The control cabinet provides enclosure to house the controls and wiring. Customer should verify the components and connection types prior to ordering.
Sanitary design of the pump allows it to come in contact with foods and ingredients. Customer should evaluate the material of contact with the product to determine its suitability.
The applications of this configuration are to transfer tomato paste to and from various stages of the tomato processing and filling line. Tomato paste can vary in viscosity and contain particles. Therefore, it is important to understand the characteristics of the product being transferred to select the proper pump for the application.
The title of the literature describes a sanitary, variable speed rotary lobe pump with a hopper trolley and control cabinet. Further details on the internal components of the pump are lacking. Customer should verify these with the supplier prior to purchase.
Information needed to evaluate the suitability of the pump for a given application includes the flow rate and discharge pressure required, temperature and viscosity of the tomato paste, parts of the paste, if any, suspended in the paste, the frequency with which the pump is to be operated to transport the paste, the electrical service available at the location of installation.
This may assist the production team to position and attach the equipment to the process equipment. Check the trolley to determine its mobility and the functions of the control panel to be used in operation and to clean the equipment.
Frequently Asked Questions
What does the rotary lobe pump transfer?
This pump is to transfer tomato paste. Check to see if the paste contains any solids and verify the viscosity and temperature of the paste.
How does the rotary lobe pump operate?
The lobe of the pump creates a cavity which vacuum draws the product into the pump and pushes it to the outlet of the pump.
What is the function of the hopper trolley?
The hopper collects product to be transferred to the pump. Determine the dimensions to see if it will fit in the space available in your facility.
Will changing the speed of the inverter change the flow rate of the pump?
Yes. The inverter alters the speed of the impeller of the pump to some extent, thus adjusting the flow rate to some degree, based on the requirements of the system.
What should I verify prior to purchasing this product?
Verify the required flow and pressure of the system, power requirement of the motor, materials in contact with the product, connections, and the method of electrical supply. Also determine the frequency with which the equipment needs to be cleaned.
Can I use this pump for cleaning in place?
The pump can be used for CIP; however, for what purposes and with what frequency it should be cleaned must be determined. Consult the manufacturer for these details.
Request a Quote
To obtain a quotation, provide us with the physical properties of the tomato paste to be transferred, the flow rate and pressure required, and the electrical specifications of the equipment.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.